Characteristics
We develop the Machine from the foundation of G6805 and DZ22 series products. G6805 has been designed for multiple purposes based on years of accumulated clinical experience, acquired advantages of similar foreign products and state of the art computer technology. This brings a new image to traditional acupuncture, the concept of no puncture, no needle, yet with guaranteed therapeutic results. The Machine is well equipped with reliable functions and easily operable. The output electrodes made from high-molecular electrically conducted materials are safe and comfortable to use.
Each functional aspect of the Machine is controlled from built-in internal computer system. This Machine is extremely helpful in allowing doctors to precisely repeat treatment. Therefore, the Machine has been improved in functional capabilities to prevent any shortcomings which existed in earlier products. This Machine is convenient for home use with the consultation from your physician.
Technical Specifications
1. Model: Category II, BF Model
2. Specified load: 500W
3. Power: AC 10VA DC 1W
4. No external replaceable fuse. Internal fuse: RT1-20 0.5A
5. Weight: 0.9 Kg
6. Dimension (length x width x height): 220 mm x 150 mm x 80 mm
7. Continuous operation time: DC 1.5 hrs., AC 4 hrs.
8. Dermo-electrodes for treatment: Electrically conducted rubber electrodes, Electrode clips for ear points
9. Size of umbrella-shaped electrically conducted rubber electrodes: Diameter of doom: 10.5mm Length of handle: 10mm
10. Operation conditions:
Temperature: 5°C ~ 40°C
Relative humidity: < 80%
Air pressure: 100 ± 4kPa
Storage conditions:
Temperature: -5°C ~ 40°C
Relative humidity: < 80%
Air pressure: 100 ± 4kPa
11. Voltage range of power source:
AC: 95V-265V 50Hz or 60Hz;
DC: 6V 4 size 2 Batteries
12. Basic wave:
Pulse wave with negative-going pulse on the posterior border, component of direct current is zero.
V: Peak-to-peak Value
T: Pulse period, pulse frequency = 1/T
Tw: Pulse width T1 = T-Tw
13. Pulse width: 0.5 ± 0.1 ms
14. Pulse frequency: 0.5 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz, 30 Hz, 40 Hz, 70 Hz, 100 Hz (± 15% difference for each frequency).
15. Output wave modes: Continuous wave, Intermittent wave, Sparse-dense wave.
16. Timer: 10 minutes~45 minutes, total 8 grades. Time step 5 minutes (+ 15% difference for each grade)
17. Maximum output voltage (P-to-P value): 65V (with 500 W load)
18. Interval: 4 ± 1 seconds for intermittent and sparsedense waves
19. Open circuits output voltage (P-to-P value) of each output is less than 500V
20. The charge quantity of single pulse is greater than 7ms
21. Maximum energy of single pulse is less than 300mJ
22. Alternation of output load has no influence on output frequency, pulse width and pulse shape. The change of output load will affect the P-to-P value of output
Voltage: (see table) Load(W) 100 200 500 1000 5000 10000 open circuit
Output Voltage 20 30 65 100 220 250 350
Accessories:
1. Output cords: (2+2) sets
2. Electrically conducted rubber electrodes (umbrella-shaped): 8 sets
3. Paste paper: 40 sets
4. Ear-point electrode clips: 1 set
5. Point-detecting electrode: 1 set
6. Electrically conducted glue: 1 box
Reviews
There are no reviews yet.